AIR Wholesalers has a significant range of Electrical Components.

  • Capacitors – Run & Start
  • Circuit Breakers – Schnieder Electric
  • Contactors – Schnieder Electric
  • Heater Cable
  • Isolators
  • Overloads
  • Relays
  • Remote Controls
  • Thermostats
  • Timers
  • Voltage Monitors

Showing 1–24 of 29 results

AKO Compressor Crankcase Heaters

AKO Compressor Crankcase Heaters

Universal resistance for hermetic compressors. They prevent the refrigerant absorbing oil and are suitable for any type of compressor in a cylindrical or oval shape, boiler or tank.

AKOCABLE - AKO711XX - Constant Wattage Heating Cable

AKO Constant Wattage Heating Cable (Fluoropolymer Covering)

Exposure temperature up to 200ºC with fluoropolymer covering. Used in electrical heat tracing for temperature maintenance up to 190ºC in pipes, tanks, surfaces, etc., in areas exposed to chemicals and corrosive environments and in hazardous areas.

AKO-5231 Constant Wattage Heater Cable

AKO Constant Wattage Heating Cable (PVC Insulation)

Exposure temperature up to 70 ºC with PVC high temperature insulation. PVC insulation. Copper conductors 2 x 1,5 mm2. Nominal outer dimensions 7 x 9,5 mm. Suitable for low temperature applications.

AKOCABLE - AKO701XX - Constant Wattage Heating Cable

AKO Constant Wattage Heating Cable (Silicon Insulation + Fluoropolymer Covering)

Exposure temperature up to 180ºC with fluoropolymer covering. Used in electrical heat tracing for temperature maintenance up to 155 ºC in pipes, tanks, surfaces, etc., in areas exposed to chemicals and corrosive environments and in hazardous areas.

AKOCABLE - AKO5234 - Constant Wattage Heating Cable

AKO Constant Wattage Heating Cable (Silicon Insulation)

Exposure temperature up to 180 ºC with silicone insulation. Suitable for avoiding ice in pipes and metal surfaces or for heating not exceeding 55ºC on them. It can be cut to size.

AKOCABLE - AKO712545 - Constant Wattage Heating Cable

AKO Constant Wattage Heating Cable (Silicon Insulation)

Exposure temperature up to 180ºC with silicone insulation. PVC insulation. Copper conductors 2 x 1,5 mm2. Nominal outer dimensions 7 x 9,5 mm. Suitable for low temperature applications.

AKOCABLE - AKO7124X - Self-regulating Heating Cable

AKO Self-Regulating Heating Cable (Flouoropolymer Covering)

Exposure temperature up to 120ºC with Flouoropolymer covering. Adjust power output in line with the temperature in the pipe. It can be cut to size. Maximum temperature for continuous exposure: 120ºC. For electric heating of pipes and tanks, in maintaining temperatures when steam cleaning is performed.

AKOCABLE - AKO7124X - Self-regulating Heating Cable

AKO Self-Regulating Heating Cable (Flouoropolymer Covering)

Exposure temperature up to 220ºC with Flouoropolymer covering. The self-regulating heating cables AKO-7126x are suitable for frost protection and temperature maintenance for receptacles, pipes an valves, up to 200ºC.

AKOCABLE - AKO712XX - Self-regulating Heating Cable

AKO Self-Regulating Heating Cable (Fluoroploymer Covering)

Exposure temperature up to 65ºC with Fluoroploymer covering. Adjust power output in line with the temperature in the pipe. It can be cut to size. Maximum temperature for continuous exposure: 65ºC. For electric heating of pipes and tanks, in maintaining temperatures when steam cleaning is NOT performed.

AKOCABLE - AKO122XX - Self-regulating Heating Cable

AKO Self-Regulating Heating Cable (Polyolefin Insulation + Metal Braid)

Exposure temperature up to 65ºC with braid for ground connection. Is used mainly for protection against ice formations in pipes and tanks. It can also be used to maintain temperatures of up to 65°C and are adequate for the following Pipe material or surfaces to trace – Carbon & Stainless Steels & Plastic Pipes.

AKOCABLE - AKO712XX - Self-regulating Heating Cable

AKO Self-Regulating Heating Cable (Polyolefin Insulation)

Exposure temperature up to 65ºC with Polyolefin Insulation. Is used mainly for protection against ice formations in pipes and tanks. It can also be used to maintain temperatures of up to 65°C and are adequate for the following Pipe material or surfaces to trace – Carbon & Stainless Steels & Plastic Pipes.

AKOCABLE - AKO712XX - Self-regulating Heating Cable

AKO Self-Regulating Heating Cable (suitable Explosive Zones)

Exposure temperature up to 65ºC suitable for Explosive Zones. Adjust power output in line with the temperature in the pipe. It can be cut to size. Maximum temperature for continuous exposure: 65ºC. For electric heating of pipes and tanks, in maintaining temperatures when steam cleaning is NOT performed.

AKOCABLE - AKO7124X - Self-regulating Heating Cable

AKO Self-Regulating Heating Cable (TPC Covering)

Exposure temperature up to 110ºC with TPC covering, suitable for Explosive zone. Adjust power output in line with the temperature in the pipe. It can be cut to size. Maximum temperature for continuous exposure: 110ºC. For electric heating of pipes and tanks, in maintaining temperatures when steam cleaning is performed.

Goodspec 30amp RelayGoodspec 30amp Relay

Goodspec 30amp Heavy Duty / High Current Relay

The HLR1000-240AT1H1Q is a 30 amp single pole 240V ac coil high power relay used in refrigeration and cool room installations where the temperature control’s internal relay lacks the power switching capability to reliably control the compressors high load.

Add to my quote

ICM492 Single Phase Monitor

ICM Single Phase Digital Line Voltage Monitor

Reliable protection of single phase systems against adverse line voltage conditions. Constantly monitors and displays line voltage. Protects against Over and Under voltage, and Rapid Short Cycling caused by Transient Faults and Power Interruptions.

Add to my quote

ICM450 Three Phase Monitor

ICM Three Phase Digital Line Voltage Monitor

The ICM450 was specifically designed to protect motors and other 3-phase loads from premature failure and damage due to common voltage faults such as voltage unbalance, over/under voltage, phase loss, reversal, incorrect sequencing and rapid short cycling.

Add to my quote

ICM UMSR-50 Universal Relay

ICM Universal Motor Start 50amp Relay

ICM’s new Universal Motor Starting Relay incorporates patented differential voltage sensing and a non-positional mounting configuration to offer a single replacement for all standard potential relays. Great way to reduce inventory. Ideal for A/C, commercial refrigeration, heat pump or any single-phase motor application up to 10 HP.

Add to my quote

IP66 Isolator

Isolation Switches – IP66

The UFK Series of Weather protected isolating switches is a robust range of Switches suitable for virtually any external application.

MJB 30a 240v Relay

MJB 30amp Heavy Duty / High Current Relay

The 841-1C-30-240 is a 30 amp single pole 240V ac coil high power relay used in refrigeration and cool room installations where the temperature control’s internal relay lacks the power switching capability to reliably control the compressors high load.

Add to my quote

Motor Run Capacitor

Motor Run Capacitors P2 Protection

Designed for continuous duty, the run capacitor always remains energized and connected in the motor’s electrical circuit.

Motor Start Capacitor

Motor Start Capacitors

Giving the motor an initial “push” on start-up, briefly increasing its starting torque and allowing the motor to be cycled on and off quickly.

CABAC HD UV Cable Ties

Nylon Heavy Duty UV Cable Ties

Made from Polyamide 6,6, Halogen Free Cable Tie, HEAVY DUTY Head/pawl integrally moulded for added strengthSmooth round edges, safe and will not cut insulation, UV stabilised for outdoor use